PPG INDUSTRIES -- WAX & GREASE REMOVER, DX330 -- 8010-00F006017
===================== Product Identification =====================
Product ID:WAX & GREASE REMOVER, DX330
MSDS Date:01/01/1987
FSC:8010
NIIN:00F006017
=== Responsible Party ===
Company Name:PPG INDUSTRIES/CLEVELAND, OH 44111
Emergency Phone Num:(304) 843-1300
CAGE:EO498
=== Contractor Identification ===
Company Name:PPG INDUSTRIES INC
Address:4325 ROSANNA DR
Box:City:ALLISON PARK
State:PA
ZIP:15101
Country:US
Phone:412-492-5555
CAGE:88373
Company Name:PPG INDUSTRIES/CLEVELAND, OH 44111
CAGE:EO498
============= Composition/Information on Ingredients =============
Ingred Name:NAPHTHA (PETROLEUM SPIRITS OR BENZIN)
CAS:8030-30-6
RTECS #:SE7555000
Fraction by Wt: 75%
OSHA PEL:100 PPM
===================== Hazards Identification =====================
Effects of Overexposure:SKIN, EYE & RESP TRACT IRRIT/CNS
DEPRESSION/HEACHE/DIZZINESS/STAGGERING GAIT/CONFUSION OR COMA.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE FROM EXPOSURE. RESTORE BREATHING. NOTIFY
PHYSICIAN. EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. TAKE TO
PHYSICIAN FOR DEFINITIVE MEDICAL TREATMENT. SKIN: WASH WITH WATER.
REMOVE CONTAMINATED CLOTHING. CONSULT PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point:54F PMCC
Lower Limits:1.0%
Extinguishing Media:CO2, DRY CHEMICAL OR FOAM
Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE. FOG NOZZLES
ARE PREFERABLE.
Unusual Fire/Explosion Hazard:WATER TO COOL CLOSED CONTAINERS TO
PREVENT PRESSURE BUILD-UP & POSSIBLE AUTOIGNITION OR EXPLOSION.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAMES, HOT
SURFACES & ELECTRICAL, STATIC OR FRICTIOL SPARKS). AVOID BREATHING
VAPORS. VENTILATE AREA. REMOVE WITH INERT ABSBENT & NON-SPARKING
TOOLS.
====================== Handling and Storage ======================
Handling and Storage Precautions:DON'T STORE >120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED & PROTECTED FOR STORAGE OF
NFPCLASS IB FLAMMABLE LIQUIDS. DON'T TAKE INTERNALLY.
Other Precautions:INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING &
INHALING CONTENTS CAN BE HARMFUL OR FATAL. CONTAINERS SHOULD BE
GROUNDED EN POURING. AVOID FREE FALL OF LIQ IN EXCESS OF A FEW
INCHES.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:CONFINED AREAS, WEAR SCBA OR SUPPLIED AIR
RESPIRATORY PROTECTION.
Ventilation:PROVIDE LOCAL EXHAUST VENTILATION TO KEEP AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:100%
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:FUMES MAY CONTAIN: CO
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE &
FEDERAL REGULATIONS. DON'T INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.